Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: (ASCEND) o's in PRI display



On 01:15 PM 6/10/97 -0700, you shaped the electrons to say...
>There is a difference between switches as to how they do B-channel
>initialization, which with NI-2 is supposed to be standard now. Most likely
>the configuration does not match what telco has at the switch. 

I have a trouble ticket #113284 open right now...  everything is configured
for NI-2 and the really weird thing is that the P400 is accepting calls
just fine... the o's seem to replace the standard "-"... I dunno... the LEC
has completely torn down my circuit and rebuilt it on a different trunk....

A woman named "Wei" (my tech) asked me to fax her the PRI debug information
(which I have) and we'll see what she comes up with...

Also, she also told me that my Pipeline 400/T1 would accept TWO pri's just
fine... I am just stupid (I've read the documentation and that's not what
it says) or is Wei just misinformed?

-Richard
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
* Richard Yoo                                phone: (210)930-1902     *
* Cymitar Network Systems                      fax: (210)804-1177     *
* P.O. Box 12096                            email: <ryoo@cymitar.net> *
* San Antonio, TX 78212-0096            WWW: <http://www.cymitar.net> *
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

++ Ascend Users Mailing List ++
To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd:	<http://www.shore.net/~dreaming/ascend-faq>