Re: (ASCEND) switched 56 setup on max 4000



Kevin,

Another MAX is connected to a channelized T1 line.
Do I have to do something different? and will all
the conversions still take place at the CO?

MAX---Channelized T1---Telco---SW56---Router

Thanks for your help,

Chris

>>Here's my setup:
>>
>>	MAX---PRI---Telco---SW56---router
>
>          ^^^^^^^       ^^^^^^^^^^
>          ISDN Sig       Inband Sig
>
>>If the router dials into the MAX using in-band signaling,
>>will the MAX autodetect that the incoming call is a switched
>>56 call, and it will switch to in-band signaling instead 
>>of the D channel?
>
>No. The telco does all of the translation. When an inband
>56K call transverses a switch (telco) and is routed onto a
>PRI line, the telco does all of the translation needed. The call
>is presented to the MAX as a 56K data call - exactly as it would
>if the call was originated as an ISDN 56K data call. The MAX talks
>to the switch over the D-channel, and the switch talks to the sw56
>router with inband signalling. The data is unaffected by the change
>in signalling method.
>
>>My MAX can accept ISDN and analog calls already.  If the
>>MAX autodetects the switched 56 calls, then I guess I don't
>>have to configure my MAX to accept SW56 calls at all.
>
>Correct.