(ASCEND) Fw: Cisco / MAX4000 callback ?
Forwarded by Pierre-Yves Kerembellec <Pierre-Yves.Kerembellec@vtcom.fr>
---------------- Original message follows ----------------
From: Pierre-Yves Kerembellec <Pierre-Yves.Kerembellec@vtcom.fr>
To: ascend-users@max.bungi.com, support@ascend.com
Date: Tue, 20 May 1997 18:08:45
Subject: Cisco / MAX4000 callback ?
--
Hi !
I'm trying to get the following connection working :
1) a Cisco 2003 call a MAX4000, and successfully passes
CHAP authentication (I use a 'ppp authentication chap callin'
at the Cisco side ...)
2) the MAX4000 hang-up, then callback the configured number
3) the Cisco answers the call and re-authenticate using CHAP
again
Phase 1 works fine
Phase 2 does not happen, because the MAX _NEVER_ terminates the call !
I've got the following RADIUS profile :
thecisconame Password = "thepassword"
User-Service = Framed-User,
Framed-Protocol = PPP,
Framed-Address = 193.XXX.XXX.14,
Framed-Netmask = 255.255.255.248,
Ascend-Idle-Limit = 900,
Ascend-Callback = Callback-Yes,
Ascend-Send-Auth = Send-Auth-PAP,
Ascend-Send-Passwd = "thepassword",
Ascend-Dial-Number = "014612XXXX",
Ascend-Data-Svc = Switched-64K
Why does my MAX never callback the Cisco ?
What sofware image do I need to support callback ?
(currently running 5.0Ap7, eim.m40)
How can I test that the MAX4000 is able to dialout ?
(used 'test #number' under TermServ, but this failed)
Do you have some profile examples that works ?
NB: I cannot use CLID authentication since the Cisco won't
validate callback until fully authenticated wia PAP or CHAP
to the other end ...
NB2: if I don't use the callback feature, all goes like a charm !
(I mean, the Cisco perfectly connect to the MAX4000, and correctly
aggregate the second B channel when needed)
Please, help me, I'm getting crazy about that !!! ;-)
Pierre-Yves
=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=
Pierre-Yves KEREMBELLEC Phone # +33 1 46 12 67 50
VTCOM Fax # +33 1 46 12 67 00
40, rue Gabriel Crie E-mail pyk@vtcom.fr
92245 Malakoff Cedex, France Systemes et Reseaux
=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=
++ Ascend Users Mailing List ++
To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd: <http://www.shore.net/~dreaming/ascend-faq>
or <ftp://ftp.shore.net/members/dreaming/ascend-faq.txt>
Follow-Ups: