Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: (ASCEND) Callback doesn't work if too quick (5.0A)



Nope - still get a LAN security error.  Thanks for the try, though!

Ray

> Try to set the
> Use Default Answer Profile
> to No in the Max2000 configuration, and repeat your test....

> I'd really like to know ;-)

> Paul

> Dans son message (In his/her message), Ray Davis ecrivait (wrote) :
> > We have a problem where some P50s set to callback can connect to our
> > Max by itself with no problem, but when we dial it and it calls back
> > we get a LAN security error.
> > 
> > Max2000/E1 (5.0A) with a connection profile to a P50:
> >     AnsOrig=Both
> >     Callback=No
> >     Exp Callback=Yes
> > 
> > A P50 (4.6Cp11 or 5.0A) with a connection profile to the Max:
> >     AnsOrig=Both
> >     Callback=Yes
> >     Exp Callback=No
> > 
> > When the Max initiates a call to the P50 its syslog says:
> > 
> > May 28 13:41:31 max2000 ASCEND: slot 5 port 1, Outgoing Call, 01234567890
> > May 28 13:41:36 max2000 ASCEND: slot 0 port 0, line 1, channel 19, Incoming Call, 1239999990
> > May 28 13:41:36 max2000 ASCEND: slot 5 port 2, Assigned to port, 1239999990
> > May 28 13:41:38 max2000 ASCEND: slot 5 port 2, line 1, channel 19, Call Connected, 1239999990
> > May 28 13:41:38 max2000 ASCEND: call 78 AN slot 5 port 2 64K 987600
> > May 28 13:41:41 max2000 ASCEND: slot 5 port 2, LAN security error, custp50
> > May 28 13:41:41 max2000 ASCEND: slot 5 port 2, Call Terminated
> > May 28 13:41:41 max2000 ASCEND: call 78 CL 0K   c=101 p=67
> > May 28 13:41:51 max2000 ASCEND: call 77 CL 0K   c=2 p=2
> > May 28 13:41:51 max2000 ASCEND: slot 5 port 1, Call Terminated
> > May 28 13:41:51 max2000 ASCEND: slot 0 port 0, line 1, channel 2, No Connection
> > 
> > If I initiate a call to the P50 using ^D 1 and then immediately
> > kill it with ^D 2 before the callback comes it then there is no
> > problem.
> > 
> > These same P50 profiles worked with callback just fine with a P400
> > running 4.5.
> > 
> > Note that the number the Max dials is different than the number the
> > P50s dial back in with, but Dial and Calling number are set up
> > properly or the P50s would never get a LAN session up.
> > 
> > Any ideas?  Is this a known problem?
> > 
> > Thanks,
> > Ray
> > ___
> > Ray Davis                               carpeNet Information Technologies GmbH
> > ray@carpe.net    http://www.carpe.net/    +49-6192-901440  +49-6192-901441 fax
> > ---------------------*   carpe diem...  carpe net!   *------------------------
> > ++ Ascend Users Mailing List ++
> > To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
> > To get FAQ'd:	<http://www.shore.net/~dreaming/ascend-faq>
> > or		<ftp://ftp.shore.net/members/dreaming/ascend-faq.txt>
> > 


> Paul Rolland, rol@oleane.net
> OLEANE SA/Service Technique/Responsable Backbone & Telecom
> OLEANE SA/Technical Service/Backbone & Telecom Manager

> --

> Support technique et operationnel Oleane :  support@oleane.net
> Gestion du service des news et des feeds :  newsmaster@oleane.net
> Test du mail                             :  ping@oleane.net
> Informations commerciales sur Oleane     :  info@oleane.net

> Please no MIME, I don't read it - Pas de MIME, je ne le lis pas

> If a train station is where a train stops, what is a workstation then ?
++ Ascend Users Mailing List ++
To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd:	<http://www.shore.net/~dreaming/ascend-faq>
or		<ftp://ftp.shore.net/members/dreaming/ascend-faq.txt>