Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

(ASCEND) 56K ISDN wont connect to TNT



Were having problems connecting customers using ISDN at 56K.

We have a number of users with 64K and they are fine. 

Tried using Force 56 - didnt do anything.

Tested PRI's - Fine

Tested BRI's - fine

How can I fix this!!


>From Prev Post:

The Telco has no solutions, in fact says nothing is wrong at all.

<excerpt>In one case the connection is ascend to ascend with all curent
firmware.We have a TNT with 1.3ap5. Our PRIs deliver analog and ISDN
calls to the box.

The customer has a P75 on 5.1a. We as an ISP use this box as the POP.

We have no problem with users by modem, or with ISDN 64K users in all
cases except one.


The Problem: 

Then I attempt to dial my TNT with data service set to 64K, It dosent
place the call at all.

If I put the P75 into 56K data service it will place the call (confirmed
on the TNT) but CRCs and never logs in.


Keep in mind other P50's P75s and Ramps are fine but all at 64K, not 
56K


According to the telco they have confirmed that the customer has 64K per
channel from the swich we will call "DI"(Desert Inn).

The TNT's PRIs are connected with 64 per channel to our switch we call
"DM1" (Downtown Main 1) which we are around the corner from.

** note there is also a "DM2" (Main 2) which is in the same telco
building.


We first used the telcos loop test number which dialed at 64K fine. Hmmm.
Well it turns out that the loop # in in DM2.

After diging a little deeper we establish that well each of us have 64K
to the switch, beetween DI and DM1 there is only 56K. (DI to DM2 has
64K)

Telco finds another loop # in my DM1 - Dosent dial in 64K - CRC's in
56K.

*note - an ascend tech was able to place (long dist) both 64K and 56K
calls to the TNT but still CRC'd with both speeds to death - he also
telnet'd in and checked the TNT config - a-OK

**Three weeks of my life lost to poor engineering - If only one of my
PRI's went to the other switch.


All arrestors on both circuits are gas.


Does anyone have any suggestions?

</excerpt>

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

Christopher Beaumont


Intuitive Logic

111 N. 7th St.       Las Vegas,     NV    89101

Phone (702)386-0010<color><param>ffff,0000,0000</param>     </color>Fax
(702) 386-1078

Signed or Encrypted Messages Preffered 

PGP Public Key ID 0xB2893691

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

++ Ascend Users Mailing List ++
To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com