Dear Matt,
>Have you tried at+ms=11,1,300,48000 at all?
>
>+MS= <mod> [,[<automode>][,[<min_rate>][,[<max_rate>]]]]<CR>
Yes, But we have the same problem.
I solved the problem following command.
"AT-answer-string = at+ms=,,,46000 "
I have found a mistake in TAOS 7.0.0 Document.
Following is the text of TAOS 7.0.0 Document .
=========================================================================
[in TERMINAL-SERVER:modem-configuration]
AT-answer-string = ""
The value of this parameter must be valid AT commands, up to 36 characters.
Do not begin the string with AT. <- simething wrong ?
An AT is automatically appended to the beginning of this string, before it is sent
to the modem.
==========================================================================