Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: (ASCEND) SNMP Set to Reboot Max
On Thu, 8 Jan 1998, Michael Medwid wrote:
> In order to maintain stability, I would like to create a cron job to boot
> the Max 4004 once a week.
> Is there an settable SNMP variable that I can use to reset the Max? Anyone
> else do something
> similar?
The following appears in the Ascend enterprise mib, however,
I dont find it on my 400's, but I do see it on my pipeline220
(Running 5.0Ap38 on the 4000's, and 5.1Ap4 on the p220)
(My p220 is production and has been up for 54 days, I dont want to try it
:) )
its .1.3.6.1.4.1.529.9.8.0 , set it to 2.. In theory..
sysReset OBJECT-TYPE
SYNTAX INTEGER {
no-op( 1 ),
reset( 2 )
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "The reset takes effect after 1 minute."
::= { systemStatusGroup 8 }
----
Jason Ackley
++ Ascend Users Mailing List ++
To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd: <http://www.nealis.net/ascend/faq>
References: