Real Time Ascend Maling List Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: (ASCEND) RE: connecting from MAX4k to P50 using NAT
I have configured several profile (in RADIUS for the Max4k) to dial out to
remote P50/P75 (not running NAT though) and they all working fine. I
bascially do the same for this P50 (running NAT). Here is the profile:
client-out Password ="ascend", User-Service = Dialout-Framed-User
User-Name = "max002",
User-Service = Framed-User,
Framed-Protocol = MPP,
Ascend-Dial-Number = "9xxxxxxx",
Ascend-Send-Auth = Send-Auth-PAP,
Ascend-Send-Passwd ="xxxxxx",
Framed-Address = xxx.xxx.xxx.xxx,
Framed-Netmask = 255.255.255.0,
Ascend-Data-Svc = Switched-64K,
Ascend-Base-Channel-Count = 1,
Ascend-Maximum-Channels = 2,
Ascend-Idle-Limit = 60
and both P50 and Max4k were set to be able to ans/orig the call.
and the P50 has a delicated IP address too.
Any ideas?
Daniel
At 09:39 PM 6/21/99 +0200, you wrote:
>Yes, I did the same thing (NAT and the max calls a pipe50). Maybe the
>problem is in the Connection->Telco Settings, there you need (on the max
>and on the pipe) set Answer-Orig to both (we have a max4000). But the pipe
>needs a fixed ip and I set up the connection profile on the max (not with
>radius).
>
>Hope that helps.
>
>Rgs
>Michael Saladin
>
>
>>Hi there,
>>
>>We have setup a pipeline P50 using NAT for a client connecting to our
>>Max4048. In this case, we have to set it up so that the P50 can connect to
>>the Max and the Max can also connect to the P50 once there is a network
>>request.
>>(the client will have their own ftp,web server and we have put static
>>mapping in place)
>>
>>The P50 can connect to the Max with no problem but the Max cannot connect
>>to the p50. When the Max try to connect to P50, it will connect and then
>>disconnect within a second. I have tried set the REV-AUTH in the P50 to
>>empty and it did connect but nothing will go through.
>>
>>I now use REC-AUTH = PAP on the P50 and both send and receive password are
>>the same.
>>
>>My question is : Can I make the Max connect to the P50 (running NAT) ?
>>If yes, how?
>>
>>Thanks
>>
>>Daniel
>>
>>++ Ascend Users Mailing List ++
>>To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
>>To get FAQ'd: <http://www.nealis.net/ascend/faq>
>
>---------------------------------------------------------------
>Magnet.Com AG, Aliothstr. 60, CH-4142 Muenchenstein,Switzerland
>Michael Saladin Tel. ++41 61 413 13 13, Fax. ++41 61 413 13 12
>
>Email: friends@magnet.ch WWW: http://www.magnet.ch
>---------------------------------------------------------------
>
>
++ Ascend Users Mailing List ++
To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd: <http://www.nealis.net/ascend/faq>