Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: (ASCEND) Pipeline 75, 2 channels, and ACO (slight modify)




Hello


<snip>

This is a slightly modication of this thread, but...


> 
> On Sat, Nov 29, 1997 at 12:24:10PM -0500, Leon McCalla wrote:
> > I think the problem has to do with the ascend-only MPP  Vs. MP. the Max will
> > neither do callback nor a 128K dial-out call into ISDN modems attached to NT
> > boxes. NT's Multilink and callback is part of the PPP-LCP extensions while
> > Ascends is in thier propietary MPP.
> > 
> > supposedly it will be fixed in the next incremental release but i doubt it.
> > work has already started on 6.0 and there are to many bugs in the 5.0p
> > series to begin work on an incremental release.
> > 
> > Leon McCalla.


We have pipeline 75s trying to dial into max1800's over standard 
ISDN. 

We cannot for the life of us get teh 75 to keep up two channels.

We have done all the normal setup and what not as per standard MP/MPP 
connections, but the first channel comes up and stays up, whilst the 
second attempts and then clears with cause code 16 (as per show isdn 
x)

What could we be missing? 

both ends, the channel count is at 2
both ends, the encaps is at MP or MP+
both ends, the ISDN BRI numbers are setup 

TIA

adam
+-------------------------------------------------+
| Adam Neat                |NOC Tel: 03-9887-1984 |
| National Systems Manager |NOC Fax: 03-9801-8533 |
| IPAX Systems - Australia |http://www.ipax.com.au|
| Mobile: 0414-348-187     |adamneat@ipax.com.au  |
+-------------------------------------------------+
++ Ascend Users Mailing List ++
To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd:	<http://www.nealis.net/ascend/faq>


Follow-Ups: References: