Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: (ASCEND) Pipeline 75, 2 channels, and ACO (slight modify)
> From: "Leon McCalla" <ascend@caribbeanlink.com>
> To: <adamneat@ipax.com.au>, "Stephen Fisher" <lithium@cia-g.com>
> Cc: <ascend-users@bungi.com>
> Subject: Re: (ASCEND) Pipeline 75, 2 channels, and ACO (slight modify)
> Date: Mon, 1 Dec 1997 00:43:25 -0500
> 1) check to make sure that the DBA monitor is set to none
> 2) bridging, IP routing and IPX routing as well as the IP assignments are
> set to the same thing on both sides.
> 3) if the passwords or any of the above are incorrect, it is possible that
> the MAX is forcing the P75 to use the default profile instead of the
> assigned connection profile.
>
Hi Leon
that DBA monitor was it!
flicked that and all is working fine.
You are a ledgend - we'be been muddling over this for bloody weeks
adam
+-------------------------------------------------+
| Adam Neat |NOC Tel: 03-9887-1984 |
| National Systems Manager |NOC Fax: 03-9801-8533 |
| IPAX Systems - Australia |http://www.ipax.com.au|
| Mobile: 0414-348-187 |adamneat@ipax.com.au |
+-------------------------------------------------+
++ Ascend Users Mailing List ++
To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd: <http://www.nealis.net/ascend/faq>