Re: (ASCEND) Pipeline 75, 2 channels, and ACO (slight modify)



1) check to make sure that the DBA monitor is set to none
2) bridging, IP routing and IPX routing as well as the IP assignments are
set to the same thing on both sides.
3) if the passwords or any of the above are incorrect, it is possible that
the MAX is forcing the P75 to use the default profile instead of the
assigned connection profile.

Leon McCalla

-----Original Message-----
We have pipeline 75s trying to dial into max1800's over standard
ISDN.
We cannot for the life of us get teh 75 to keep up two channels.

We have done all the normal setup and what not as per standard MP/MPP
connections, but the first channel comes up and stays up, whilst the
second attempts and then clears with cause code 16 (as per show isdn
x)

What could we be missing?

both ends, the channel count is at 2
both ends, the encaps is at MP or MP+
both ends, the ISDN BRI numbers are setup