Re: (ASCEND) dial-out on a p50 to a max1800



Kevin,

Thanks for the speedy reply, it was probably much faster than calling Ascend
tech support, and definately much less hassle.  Trouble tickets, waiting on
hold, navagating voice menus, blah... who needs it?


-----Original Message-----
From: Kevin Smith <kevin@ascend.com>


>At 02:04 PM 12/16/97 -0500, Troy Settle wrote:
>>On my P50, I have a profile with the dial# set to 1293, and it works
great.
>>But when it tries to dial for the second channel, it's attempting to dial
>>0110 (and fails since this is on a separate telco circuit). Is the P50
>>getting this information from the 1800?
>
>Yes. Via MP+ or BACP...
>
>>If so, how do I get it to dial 1294
>>instead?
>
>On the MAX1800 setup "trunk groups" to group the channels. Set the channels
>on port 1 to both '9', and on port 2 to both '8' for example. The potential
>catch here is that *IF* you dial out from the MAX, you need to remember to
>prefix the dial-out number with the relevant trunk-group number (8 or 9).