Re: (ASCEND) Strange debug errors
> The MAX400X base has 64 HDLC channels available to handle "data" sessions.
> Each ISDN call, and each channel of a nailed session use up one of
> the available channels. In your case you are *always* using 20 channels
> for the "20 channels of nailed lines", and then up to 60 additional
> channels would be needed to support the 2 PRI (E1) with ISDN/data calls.
>
> Modem calls do *NOT* use HDLC resources.
>
> If you have 44 active data/ISDN calls, then you have used up all
> available HDLC channels, and the MAX looks to see if you have any
> additional HDLC slot-cards...hence the messages in debug - since you
> don't have them. Slot cards is how you add HDLC channels up to 96/128.
Ouch. Those cards are 3500 bucks each. Looks like I will move the
nailed connections over to the 7206 - the 2 slot E1 card for that thing
is only 3000. Thanks for the info.
--
Mickey Coggins