Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

(ASCEND) SNMP on Channelized E1




Here is my problem.

I have a Chanelized E1 coming into a Max 4000.

On this E1, I defined 2 groups, group 1 and group 2.
I have a connection profile (nailed) for each group.

As the wan interface assigned to a connection profile is not
fixed, and will change each time the connection goes down and up,
I can not monitor the ifInOctets and ifOutOctets with SNMP.
(BTW, for a 256Kbps line, so a group of 4 64Kbps-channels, here
is the output of 'sh if st' on the Max:
wan58            ppp     Up     23     64000      1500     125647     104412
Well, apparently, some problems to get the real bandwidth.

Here is the output of 'sh users':
O 235943603 3:0     9:2   64K   PPP         x.x.x.x       customer_profile
Still some problems to show the bandwidth.

But if I request the variable callStatusDataRate, I get 256000.
Well...
)

I don't really care about the inconsistencies reported by the
terminal server, BUT:

does anyone know a way to get the SNMP variables on a such
interface, cleanly and definitely (I mean, without reconfiguring
my SNMP client each time the interface goes down/up :)) ?
A clean way would be to be able to access groups as if they were interfaces,
as the group number is the only fixed thing.
Or the profile name.

Any help would be greatly appreciated.

Regards.

-- 
David Ponzone / ISDnet
Pager: +33 (0)6 06 41 82 45  Cell: +33 (0)6 60 61 21 63
Email: david@isdnet.net
++ Ascend Users Mailing List ++
To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd:	<http://www.shore.net/~dreaming/ascend-faq>
or		<ftp://ftp.shore.net/members/dreaming/ascend-faq.txt>