Re: (ASCEND) P50/USR 2B aggravation



At 07:45 PM 5/29/97 -0700, Kevin Smith wrote:
>At 09:30 PM 5/29/97 -0400, Doug Wyatt wrote:
<snip>
>>The fact that it never drops before 15 minutes and always (so far) seems to
>>drop shortly thereafter has convinced me that one router or the other does
>>have a "feature" that is kicking me off.  Any other Pipeline users with
>>5.0Ap5 having trouble with 2B calls that last more than 15 minutes?
>
>Are *any* of the "timer" values *anywhere* set to about 900 ??
>
>Have to admit that I'm running 5.0Ai10 on my P75....and I have an idle timer
>to 120 seconds....so I rarely need 2-B up for that long....though I'll
>try it this evening to see *if* anything like this hits me too...
>
>I'm now set for "MP" idle timer set to 1500 - so I should stay up way
>past 15 minutes with both channels (base/min/max = 2).
>
>I'll let you know what happens (as long as no on calls me, and pre-empts
>with a voice call :).

Well I'm still connected with 2 channels after 30 minutes....for
what that's worth...


Kevin Smith                              Updated Service and Support
Ascend Communications                    Resources are now at: