Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: (ASCEND) Max4000 and Hybrid Access
At 03:14 PM 5/27/97 -0700, Bruce Robertson wrote:
>I'm trying to clarify my understanding of Hybrid Access and the 32-port
>HDLC card, on the Max 4004. Any correction of misinformation here, or
>clarification, would be helpful.
>
>1. I understand that there are a limited number (64) of HDLC channels
>on the basic Max 4004, and that I need to add the 32-port HDLC card to
>be able to use all of the PRI channels in even three PRIs, let alone
>four. Is this all that the Hybrid Access96 option is?
Yes.
>A package that
>includes the card? Or do you need the Hybrid Access96 option *and*
>the HDLC card?
The package includes the card.
>2. Does a voice call that's routed to a modem use an HDLC channel?
No.
>For example, if I have three PRIs into a 4004, and one of the PRIs is
>handling nothing but analog calls, do I need the HDLC card or Hybrid
>Access96 to handle nothing but digital calls on the other two PRIs?
No, the base system 64 HDLCs will handle the 2 PRI worth of data calls.
Kevin Smith Updated Service and Support
Ascend Communications Resources are now at:
http://www.ascend.com/service
++ Ascend Users Mailing List ++
To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd: <http://www.shore.net/~dreaming/ascend-faq>
or <ftp://ftp.shore.net/members/dreaming/ascend-faq.txt>