Hello,


Try to set the
Use Default Answer Profile
to No in the Max2000 configuration, and repeat your test....

I'd really like to know ;-)

Paul

Dans son message (In his/her message), Ray Davis ecrivait (wrote) :
> We have a problem where some P50s set to callback can connect to our
> Max by itself with no problem, but when we dial it and it calls back
> we get a LAN security error.
> 
> Max2000/E1 (5.0A) with a connection profile to a P50:
>     AnsOrig=Both
>     Callback=No
>     Exp Callback=Yes
> 
> A P50 (4.6Cp11 or 5.0A) with a connection profile to the Max:
>     AnsOrig=Both
>     Callback=Yes
>     Exp Callback=No
> 
> When the Max initiates a call to the P50 its syslog says:
> 
> May 28 13:41:31 max2000 ASCEND: slot 5 port 1, Outgoing Call, 01234567890
> May 28 13:41:36 max2000 ASCEND: slot 0 port 0, line 1, channel 19, Incoming Call, 1239999990
> May 28 13:41:36 max2000 ASCEND: slot 5 port 2, Assigned to port, 1239999990
> May 28 13:41:38 max2000 ASCEND: slot 5 port 2, line 1, channel 19, Call Connected, 1239999990
> May 28 13:41:38 max2000 ASCEND: call 78 AN slot 5 port 2 64K 987600
> May 28 13:41:41 max2000 ASCEND: slot 5 port 2, LAN security error, custp50
> May 28 13:41:41 max2000 ASCEND: slot 5 port 2, Call Terminated
> May 28 13:41:41 max2000 ASCEND: call 78 CL 0K   c=101 p=67
> May 28 13:41:51 max2000 ASCEND: call 77 CL 0K   c=2 p=2
> May 28 13:41:51 max2000 ASCEND: slot 5 port 1, Call Terminated
> May 28 13:41:51 max2000 ASCEND: slot 0 port 0, line 1, channel 2, No Connection
> 
> If I initiate a call to the P50 using ^D 1 and then immediately
> kill it with ^D 2 before the callback comes it then there is no
> problem.
> 
> These same P50 profiles worked with callback just fine with a P400
> running 4.5.
> 
> Note that the number the Max dials is different than the number the
> P50s dial back in with, but Dial and Calling number are set up
> properly or the P50s would never get a LAN session up.
> 
> Any ideas?  Is this a known problem?
> 
> Thanks,
> Ray
> ___
> Ray Davis                               carpeNet Information Technologies GmbH
> ray@carpe.net    http://www.carpe.net/    +49-6192-901440  +49-6192-901441 fax
> ---------------------*   carpe diem...  carpe net!   *------------------------
> ++ Ascend Users Mailing List ++
> To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
> To get FAQ'd:	<http://www.shore.net/~dreaming/ascend-faq>
> or		<ftp://ftp.shore.net/members/dreaming/ascend-faq.txt>
> 


Paul Rolland, rol@oleane.net
OLEANE SA/Service Technique/Responsable Backbone & Telecom
OLEANE SA/Technical Service/Backbone & Telecom Manager

--

Support technique et operationnel Oleane :  support@oleane.net
Gestion du service des news et des feeds :  newsmaster@oleane.net
Test du mail                             :  ping@oleane.net
Informations commerciales sur Oleane     :  info@oleane.net

Please no MIME, I don't read it - Pas de MIME, je ne le lis pas

If a train station is where a train stops, what is a workstation then ?