Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

RE: (ASCEND) Clocking question



At 12:01 1998/12/22 -0600, John Coy (anc.net) wrote:
>That may be what you're supposed to do, but I've found that setting
>Clock=Yes on all T1/PRIs on a MAX will save you some trouble.

>At 11:36 AM 12/22/98 -0600, "Treier, Gary R." wrote:
>>I believe that when you have more then one PRI in a MAX that Ascend
>>recommands that you have Clock Source=Yes set on one of them and Clock
>>Source=No set on the rest.

>>-----Original Message-----
>>From: Bob K [mailto:melange@yip.org]
>>- How does a MAX handle the transmission timing on multiple T1's, assuming
>>that all of them are set to Clock Source=Yes?  Does it keep the timing of

As John recommended, setting more than one trunk to "Clock Source=Yes"
will save you lots of problems when your first clocking trunk dies.

If you want to see where the clocking is from in your max,
go to debug mode then enter "clock" and it will show:

Clock source is dsl 0
Dsl#    012345678901234567...
LstSel  ?????????????????? 
Now     22---------------- 
                           
The "2" marks trunks that have "Clock Source=Yes",
with the current source on trunk 0.

-Jim H
----
Jim Howard             Sr Network Engineer        Lyceum Internet
jhoward@lyceum.com     http://www.lyceum.com/     404.248.1733     

My PGP Public Key: http://www.lyceum.com/~jhoward/pgp-key.txt
Fingerprint: 7E8B E2BA 1314 2535 CB08  CFF9 119B 7CD3 2488 954D

++ Ascend Users Mailing List ++
To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd:	<http://www.nealis.net/ascend/faq>