Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: (ASCEND) Multiple independant NFAS groups
> At 15:41 1998/06/30 -0400, Phillip Vandry wrote:
> >What about a TNT, now? What if we replaced a bunch of 4048's with a
> >single TNT. But each of the 4048's has NFAS across two lines. I want
> >to be sure it's possible to configure the distinction between 1 NFAS group
> >of 8 lines with 4 D channels, and 4 NFAS groups of 2 lines and 1 D channel
> >each.
>
> I have seen release notes for the TNT that state it can do this,
> and from what I can see on one of my 4000s, you can do it there too
> with something like this:
>
> 10-000 Net/T1
> 10-100 Line Config
> Line 1...
> Sig Mode=ISDN_NFAS
> NFAS ID num=1
> Ch 24=D-Channel
> Line 2...
> Sig Mode=ISDN_NFAS
> NFAS ID num=1
> Ch 24=Switched
> 20-000 Net/T1
> 20-100 Line Config
> Line 1...
> Sig Mode=ISDN_NFAS
> NFAS ID num=2
> Ch 24=D-Channel
> Line 2...
> Sig Mode=ISDN_NFAS
> NFAS ID num=2
> Ch 24=Switched
The "NFAS ID num" parameter is used to discrimate individual T1's within
an NFAS group, not to discriminate multiple NFAS groups. That is why
another parameter would be required for that.
By the way, "Ch 24" says "NFAS-PRIME", not "D-Channel", when NFAS is enabled.
-Phil
++ Ascend Users Mailing List ++
To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd: <http://www.nealis.net/ascend/faq>
Follow-Ups:
References: