Re: (ASCEND) LMI drops on P130
Maybe a clocking problem ? Have you verified the clock source
on this line ?
At 04:00 PM 12/16/97 -0500, Elvis Presley wrote:
>
>Just one.
>
>Resetting the unit ALWAYS brings back up the link (PVC becomes ACTIVE I
>should say which is more accurate)
>
>Once though, unplugging the unit from the smartjack and plugging back in
>brought the PVC back to active.
>
>Sounds like either the Ascend is failing to send LMI, or the frame switch
>is not listening/sending it back properly.
>
>Bill
>
>On Tue, 16 Dec 1997, Phillip Vandry wrote:
>
>> > Anyone experience LMI drops (a reset of the unit corrects the problem)
>> > on a Pipe 130 using Rev 5.0A bp13?
>>
>> We had tons of frame relay problems with a Max 1800, but I don't seem
>> to remember LMI drops.
>>
>> How many PVCs are on the line? Just one?
>>
>> -Phil
>>
>
>++ Ascend Users Mailing List ++
>To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
>To get FAQ'd: <http://www.nealis.net/ascend/faq>
>
Kevin
++ Ascend Users Mailing List ++
To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd: <http://www.nealis.net/ascend/faq>