At 05:44 PM 6/5/97 -0500, Dale Botkin wrote:
>Kevin,
>
>We were just told by tech support that there can be only one global clock
>source for a Max 4004.
There could be as many as you have T's, BUT the MAX will sync to only one.
That's the way it has *always* worked...
>Thus, if we have (for example) two CT1, a U S
>Worst frame relay line, and MCI frame relay, all from different sources,
>we can't plug them all into a 4004. Since this is exactly what we have,
>we were extremely displeased to hear this. If this is indeed true, it
>means that:
>
>1.) Two net/T1 interfaces on each of my Max 4004's go to waste;
>2.) My Maxen cannot handle frame and modem T1's as we were told
> they can;
Many do, believe me :)
>3.) I need to dig up another CSU/DSU and cable to put all my
> frame realy on a Cisco instead of moving it to the Max like I
> planned to be able to;
>4.) I suspect that we may have found the source of more than one
> elusive problem.
Describe the problems, and I can give my opinions on them....
>Comments? I heard this with a certain degree of disbelief, since it would
>seem to be a monumentally stupid way to design a box designed to handle up
>to 4 T1/PRI... nowhere in any docs we've seen does it specify that all
>four MUST have the same clock source. Ugh.
The MAX will sync to one of the T's...dependent on the clock-source settings.
If the other T's are not synchronized with that particular one, or drift
with respect to the source - then you will see frame slips on them.
The MAX buffering *will* handle very small discrepancy, but I don't recall
of the top-o-my-head what it is....
Kevin