(ASCEND) PRIs getting 'stuck'
For the longest time, we had two max4000s with 4 T1s of dialup. 1 was a
PRI and the others were just channelized T1. We just upgraded to all PRIs
and all hell broke loose. It's very odd. What happens is we will see one
B channel showing 'r' forever. Once this happens, anyone that dials in
gets a reorder and everything is hosed.
It looks like this:
-*--**r******s
If I hang up the session showing:
>A Answer
I get the message:
Far End Hung Up
Cause code 081
Another thing we are seeing is moments when everything stalls. If I were
to ping one of the PPP modem connections, I would get normal response
times and then suddenly everything stops. Then a whole pile of echos come
back with insane ping times (like a 10000 ms) and then all returns to
normal for a while.
Does anyone out there know what 'clock source y/n' does? Out of pure
desperation, I changed this parameter from N to Y and things *seemed* to
get much better (perhaps not perfect but almost normal).
I still get these stuck sessions though. I only started to see this when
I switched to PRI. We are running an odd software version 'cos we needed
a feature that was released in 4.6Ci17 so that is what we are running.
Would a software upgrade be in order here? We really need some help with
this one... It is clearly a disaster.... Before calling tech support, I
thought maybe Kevin Smith or someone else may offer some advice.
Thanks,
Steve Camas