Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

RE: (ASCEND) P75 -> Max : CL OK c=47?




On 16-Oct-97 Kevin Smith wrote:
>At 02:55 PM 10/16/97 -0000, Peter Leigh wrote:
>>
>>On 09-Oct-97 Peter Leigh wrote:
>>[nwnet connection]
>>>Ip Options:
>>>   LAN Adrs=0.0.0.0/0 [-> set this to our max's IP address / subnet]
>>>   WAN Alias=0.0.0.0 
>>>   IF Adrs=0.0.0.0/0 [ -> set this to <ip address allocated by our max> /
>32]
>>[...]
>>
>>That fixed it in that our client can now get a ppp connection. Both
>>values needed to be set as shown above.
>>
>>Question: does this indicate some problem with the max allocating IP
>>addresses (we have Pool-only=yes) or is this normal for P75s?
>
>That doesn't make sense to me. You need the MAX's IP address as you
>mention, to
>put something in the routing table for this connection. I don't see WHY you
>would need the IF Adrs though. I have it set to default 0.0.0.0 - and works
>just
>great. 

Believe it or not, that's what it took ... could it be dependent on the
max settings at all? 

- Pete.

>
>Kevin
>
Peter Leigh <pete@nwnet.co.uk>
(+44) (0)161 950 7779


++ Ascend Users Mailing List ++
To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd:	<http://www.nealis.net/ascend/faq>


References: