Re: (ASCEND) 6.1.7 and randomness of the Max IP address....




Historically, the the problems we've had with IP issues in 6.1.x are
related to OSPF.  


-rob



On Mon, 24 Aug 1998, Neale Banks wrote:

> Interesting... I'm running 6.1.7 (very plain, no OSPF or stacking) and can't
> seem to reproduce this.  My methodology was to take the output of "show
> users" and traceroute to each IP in turn - in all cases the secon-last hop
> was the ethernet interface of the MAX (and yes, we do have some customers
> using numbered interface link).  Is there something else I need to see this
> problem?
> 
> Regards,
> Neale.
> 
> At 19:38 23/08/98 -0500, Rob Myers wrote:
> >I am experiencing a strange problem similar to what you are seeing with
> >6.1.7.  When I do a traceroute to a customer's ISDN device or modem from
> >our cisco or one of our UNIX boxes I no longer get the Ethernet IP address
> >of the MAX.  I would prefer to get this address since I can find out what
> >one of our MAXen they are connected to. :)
> >
> >This is the only thing I have seen with 6.1.7 so far that I have had any
> >problems with.  I'd like to see it fixed in a future release but it is
> >more of an annoyance than a crippling problem.
> >
> >-Rob-
> >
> >> From: Raul Zighelboim <rzig@verio.net>
> >> Date: Fri, 21 Aug 1998 23:11:19 -0500
> >> Subject: (ASCEND) 6.1.7 and randomness of the Max IP address....
> >> 
> >> Hello there;  I wander is anyone else is experiencing this problem with
> >> 6.1.7:
> >> 
> >> I assigned numberred point to point links to isdn dialup; 1 /30 ip on my
> >> end, and another /30 ip in the customer end.
> >> Up to now, it all worked well.
> >> 
> >> With the last release of Ascend, the Max IP Address (used to always be
> >> the ip assigned to the Ethernet port) follows the WAN ip of the last
> >> incoming call.
> >> 
> >> So, A traceroute would show : Ethernet -> WAN13-local_ip ->
> >> WAN27-remote_ip  when it used to be :
> >>                                             Ethernet -> MAX-Ethernet_ip
> >> - -> WAN27-remote_ip...
> >> 
> >> Strange.... will Ascend ever be able to deliver code with V.90 ?  I wish
> >> the would leave 5.0p24 alone, replacing only the rockwell microcode.
> 