Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: (ASCEND) P50



At 12:00 PM 10/4/97 -0700, Jesse Martinez wrote:
>I have a user with a Pipeline 50. Not sure the rev of software he has. My
>question is how do I set up radius to allow him to connect to either of
>two maxes and route without problems. I gave him a subnet of 248 to use
>and when he connect to the first max in a hunt group he's ok. If the call
>hits the second max then he can't route. I've never configured a p50 so
>I'm not sure of the settings on his side. Both maxes are in the same hunt
>group.

Whichever MAX picks up the RADIUS entry should start advertising the route to
the P50 via a routing protocol (RIPv2 or OSPF). Do you have static routes
setup that could be over-riding this ?


Kevin


++ Ascend Users Mailing List ++
To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd:	<http://www.nealis.net/ascend/faq>